shop by category

banner

  • New

Fetal Monitor or CTG Machine

Advanced, integrated fetal monitoravailable maternal monitoring


Integrates twin’s fetal heart rate, uterine activity,fetal movement, intrauterine pressure, fetal direct ECG,maternal NIBP, SpO2, ECG and temp. monitoringAvailable with an intuitive touchscreen

Technical Specification


Physical characteristics

Dimensions 347 mm x 330 mm x 126 mm

Weight Approx. 6 Kg

 

Performance specifications

Display ---------------12” color TFT-LCD

Resolution ---------800 (h) x 600 (v)

Recorder------------ America standard;International standard;1/2/3 cm/min real-time printing                                              speed;Fast print speed (stored traces)up to 25 mm/sec

Paper ------------------Z-fold, thermosensitive

 

Battery

14.8V rechargeable Lithium-ion battery

Continual working time------------------ 4 hours

Ultrasound

Technique--------------------------------------Ultrasound pulse Dopplerwith auto-correlation

Pulse repetition rate------------------------2 KHz

Ultrasound frequency-------------------- 1.0 MHz±10%

FHR range-------------------------------------- 50 bpm - 240 bpm

Resolution------------------------------------- 1 bpm

Accuracy ---------------------------------------±1 bpm

 

DECG channel

Technique-------------------------------------- Peak-peak detection technique

FHR range -------------------------------------30 bpm - 240 bpm(American                                                                                   Standard);50 bpm - 210bpm (International Standard)

Resolution --------------------------------------1 bpm

Accuracy -----------------------------------------±1 bpm

Input impedance------------------------------ >10M (Differential, DC 50/60 Hz)

Input impedance------------------------------ >20M (Common Mode)

 

TOCO

TOCO range----------- 0% - 100%

Resolution-------------- 1%

Zero mode--------------- Automatic/manual

Non-linear--------------- ±10%

 

IUP channel

Pressure range (IUP)------------ 0-100mmHG

Resolution ---------------------------1%

Zero mode--------------------------- Automatic/manualNon-linear ±1 mmHg

 

Auto Fetal Movement (AFM)

Technique---------------- Pulsed Doppler ultrasound

Range---------------------- 0 - 100 (%)]

Resolution --------------1%Fetal movement marking; manual movement marking

 

SpO2

Measuring range-------------0% - 100%

Resolution ---------------------1%

Measuring accuracy------- 90% - 100% ±270% - 90% ±4

 

PR

Measuring range------------- 30 bpm - 240 bpm

Measuring accuracy---------±2 bpm

 

NIBP

Systolic pressure -------------50 mmHg - 240 mmHg

Mean pressure----------------- 25 mmHg - 200 mmHg

Diastolic pressure------------ 15 mmHg - 180 mmHg

Resolution------------------------ 1 mmHg

 

Temperature

Measuring range-------------- 28.0° C - 44.0° C

Accuracy -------------------------±0.2° C

16 other products in the same category: